The Tellabs 1000 MSAP E-lead and M-lead signaling (E&M) plug-in card is a special services channel unit. The E&M card supports one subscriber line circuit for E&M types I, II, III, IV and V and two subscriber line circuits configured for operation in E&M types I or V. The special services plug-in card also supports DX signaling (switched or fixed bias) and can provide subscriber line circuits for Tandem modes I and II (switch and station side) and Pulse Link Repeater (PLR) types I and II.

  • End-to-end compatibility with existing cards in the field
  • Two circuits per card, each able to support different provisioning
  • Software-provisionable E&M and PLR modes (2-wire or 4-wire)
  • Provides one or two E&M circuits per card, depending on modes: E&M Type I, II, III, IV, V and PLR I and II
  • Software-provisionable Tandem and DX modes (4-wire only)
  • Provisionable transmit and receive gain
  • Provisionable bias (switched or fixed: DX mode only)
  • Post-equalization
  • 600 ohms and 1200 ohms fixed impedances
  • Normal and reverse DX signaling

Flexible

The E&M plug-in card can provide either 2- or 4-wire service. It can only provide 4-wire service when provisioned in the Tandem or DX modes. The E&M plug-in card has a fixed impedance of 600 ohms. Voice frequency gain is provisionable in 0.1 dB increments.


Many uses

This special services card has expanded functionality with additional support for equalization and signaling, and is fully GR-57 compatible. The primary application for the E&M card is interoffice trunking from a PBX to a switch.


Software provisionable

Software provisionable E&M and PLR modes (2-wire or 4-wire) and software provisionable Tandem and DX modes (4-wire only). Provisionable transmit and receive gain and provisionable bias (switched or fixed: DX mode only).

Physical

  • Height: 5.125 in (13.018 cm)
  • Width: 0.563 in (1.429 cm)
  • Depth: 10.5 in (26.67 cm)
  • Weight: 0.5 lb (0.23 kg)


Interfaces

  • Two circuits per card


Power Consumption

  • Average power consumption: 3.0 W
  • Maximum power consumption: 8.8 W


Signaling

  • Signaling Types: n E&M Types I, II, III, IV and V - Tandem Modes I and II, Station side - Tandem Modes I and II, Switch side - PLR Types I and II - DX (fixed or switched bias)
  • Signaling delay: 50 ms maximum
  • Wink distortion for any off wink > 50 ms ±15 ms
  • On-hook interval distortion for intervals > 50 ms ±25 ms
  • Maximum loop length (E&M, PLR, Tandem modes):300 ohms
  • Maximum loop length (DX mode): 3030 ohms (including 1430 ohms for DX unit)
  • DX bridge circuit balancing: Fixed value of 1210 ohms for far-end DX bridge, plus 1120 Ohms adjustable in 16 steps for cable resistance
  • Pulse distortion: <3% at 12 pps (46%“70% break)


Audio

  • Transmit gain adjustment (toward DLC): 2-wire Terminal mode -5.5 dB to +4.5 dB, 4-wire Terminal mode -7.0 dB to +17.5 db, 4-wire Cable mode -6.0 dB to +9.0 dB
  • Receive gain adjustment (from DLC): 2-wire Terminal mode -10.0 dB to 0.0 dB, 4-wire Terminal mode -16.0 dB to +8.5 dB, 4-wire Cable mode -9.0 dB to +6.0 dB
  • Line impedance: 2-wire Terminal mode 600 ohms + 2.16 uF, 4-wire Terminal mode 600 ohms, 4-wire Cable mode 150 ohms, or 600 ohms (unloaded cable) or 1200 ohms (loaded cable)
  • Return loss (600 ohms + 2.16 uF): ERL > 28 dB and SRL > 20 dB
  • Longitudinal balance 4-wire DX mode: 200 Hz to 2 kHz, > 58 dB, 3 kHz, > 53 dB
  • Idle channel noise < 20 dBrnC
  • Supported cable configurations: 2-wire and 4-wire Terminal interface, Up to 3000 feet of intraoffice cable, but ‰¤1.5 dB 1 kHz loss - 4-wire Cable interface, Maximum cable length is limited to 10 dB 1 kHz loss or 1600 ohms DC cable resistance
  • Supported cable facilities: Nonloaded cable 19, 22, 24 and 26 gauges are supported up to 18,000-ft, including bridge taps. Maximum bridge tap length is limited to 6000 ft. All combinations are allowed. All loops longer than 18,000 ft must use H-88 loading - Loaded cable Only H-88 loading is supported. 19, 22, 24 and 26 gauges are supported, including any gauge combinations.


Environmentals

  • Operating temperature: -40 F to +149 F (-40 C to +65 C)
  • Relative humidity: 5%-95% noncondensing


Compliance

  • GR-57-CORE
  • GR-1089-CORE (for lightning and power cross)


LED Indicators

  • Green, BUSY - The E&M plug-in card is busy or is being tested; do not remove from service
  • Red, FAIL - The unit has failed
  • Blinking Red, FAIL - Illegal signaling


Software Support

  • Minimum base software FP15 and higher


Installations

  • Supported in Tellabs 1000 CBA

E&M Special Services (E&M) Plug-in Card

SKU: 0110-0238 Category:

The Tellabs 1000 MSAP E-lead and M-lead signaling (E&M) plug-in card is a special services channel unit. The E&M card supports one subscriber line circuit for E&M types I, II, III, IV and V and two subscriber line circuits configured for operation in E&M types I or V. The special services plug-in card also supports DX signaling (switched or fixed bias) and can provide subscriber line circuits for Tandem modes I and II (switch and station side) and Pulse Link Repeater (PLR) types I and II.

E&M Special Services (E&M) Plug-in Card

Features

  • End-to-end compatibility with existing cards in the field
  • Two circuits per card, each able to support different provisioning
  • Software-provisionable E&M and PLR modes (2-wire or 4-wire)
  • Provides one or two E&M circuits per card, depending on modes: E&M Type I, II, III, IV, V and PLR I and II
  • Software-provisionable Tandem and DX modes (4-wire only)
  • Provisionable transmit and receive gain
  • Provisionable bias (switched or fixed: DX mode only)
  • Post-equalization
  • 600 ohms and 1200 ohms fixed impedances
  • Normal and reverse DX signaling

Features

Flexible

The E&M plug-in card can provide either 2- or 4-wire service. It can only provide 4-wire service when provisioned in the Tandem or DX modes. The E&M plug-in card has a fixed impedance of 600 ohms. Voice frequency gain is provisionable in 0.1 dB increments.


Many uses

This special services card has expanded functionality with additional support for equalization and signaling, and is fully GR-57 compatible. The primary application for the E&M card is interoffice trunking from a PBX to a switch.


Software provisionable

Software provisionable E&M and PLR modes (2-wire or 4-wire) and software provisionable Tandem and DX modes (4-wire only). Provisionable transmit and receive gain and provisionable bias (switched or fixed: DX mode only).

Specifications

Physical

  • Height: 5.125 in (13.018 cm)
  • Width: 0.563 in (1.429 cm)
  • Depth: 10.5 in (26.67 cm)
  • Weight: 0.5 lb (0.23 kg)


Interfaces

  • Two circuits per card


Power Consumption

  • Average power consumption: 3.0 W
  • Maximum power consumption: 8.8 W


Signaling

  • Signaling Types: n E&M Types I, II, III, IV and V - Tandem Modes I and II, Station side - Tandem Modes I and II, Switch side - PLR Types I and II - DX (fixed or switched bias)
  • Signaling delay: 50 ms maximum
  • Wink distortion for any off wink > 50 ms ±15 ms
  • On-hook interval distortion for intervals > 50 ms ±25 ms
  • Maximum loop length (E&M, PLR, Tandem modes):300 ohms
  • Maximum loop length (DX mode): 3030 ohms (including 1430 ohms for DX unit)
  • DX bridge circuit balancing: Fixed value of 1210 ohms for far-end DX bridge, plus 1120 Ohms adjustable in 16 steps for cable resistance
  • Pulse distortion: <3% at 12 pps (46%“70% break)


Audio

  • Transmit gain adjustment (toward DLC): 2-wire Terminal mode -5.5 dB to +4.5 dB, 4-wire Terminal mode -7.0 dB to +17.5 db, 4-wire Cable mode -6.0 dB to +9.0 dB
  • Receive gain adjustment (from DLC): 2-wire Terminal mode -10.0 dB to 0.0 dB, 4-wire Terminal mode -16.0 dB to +8.5 dB, 4-wire Cable mode -9.0 dB to +6.0 dB
  • Line impedance: 2-wire Terminal mode 600 ohms + 2.16 uF, 4-wire Terminal mode 600 ohms, 4-wire Cable mode 150 ohms, or 600 ohms (unloaded cable) or 1200 ohms (loaded cable)
  • Return loss (600 ohms + 2.16 uF): ERL > 28 dB and SRL > 20 dB
  • Longitudinal balance 4-wire DX mode: 200 Hz to 2 kHz, > 58 dB, 3 kHz, > 53 dB
  • Idle channel noise < 20 dBrnC
  • Supported cable configurations: 2-wire and 4-wire Terminal interface, Up to 3000 feet of intraoffice cable, but ‰¤1.5 dB 1 kHz loss - 4-wire Cable interface, Maximum cable length is limited to 10 dB 1 kHz loss or 1600 ohms DC cable resistance
  • Supported cable facilities: Nonloaded cable 19, 22, 24 and 26 gauges are supported up to 18,000-ft, including bridge taps. Maximum bridge tap length is limited to 6000 ft. All combinations are allowed. All loops longer than 18,000 ft must use H-88 loading - Loaded cable Only H-88 loading is supported. 19, 22, 24 and 26 gauges are supported, including any gauge combinations.


Environmentals

  • Operating temperature: -40 F to +149 F (-40 C to +65 C)
  • Relative humidity: 5%-95% noncondensing


Compliance

  • GR-57-CORE
  • GR-1089-CORE (for lightning and power cross)


LED Indicators

  • Green, BUSY - The E&M plug-in card is busy or is being tested; do not remove from service
  • Red, FAIL - The unit has failed
  • Blinking Red, FAIL - Illegal signaling


Software Support

  • Minimum base software FP15 and higher


Installations

  • Supported in Tellabs 1000 CBA

News Releases

Corporate news releases recognizing significant achievements of Tellabs operations, products, solutions and customers.

Case Studies

Hear directly from our customers about their successful installations, quantifiable benefits and sincere testimonials.

Events

Up-coming conferences, seminars and webinars where Tellabs products, solutions and people will be actively participating.

Blogs & Articles

Read these short, and regularly updated, opinion pieces covering contemporary industry and technology topics.

White Papers

Download our non-vendor specific overviews meant to help readers understand an issue, solve a problem, or make a decision.

Videos

Media to educate and advocate our products, technologies or services, and offer direct insight into our customer references and user case studies.

Enterprise

Tellabs Optical LAN is a true enterprise centric solution that offers a better means of designing and operating networks inside buildings and across extended campuses.

Broadband

Tellabs 1000 MSAP (aka T1000, DMAX, AFC, UMC) is the industry’s only Broadband Digital Loop Carrier platform that converges legacy copper and modern fiber connectivity.

Technical Assistance Center

Address your questions and challenges quickly with our award winning TAC. Flexible support options to meet your needs.

Professional Services

From small projects to migrations to full turn key services, Tellabs is here to help.

Training

Preparation is the key to success.  Get your team ready to plan, deploy and manage your Tellabs Network. Check our our Training Curriculum today!

Credentials

You worked hard in Training, now it's time to show your new credentials off to the World through our Digital Credentialing Program!

Become a Partner

The Tellabs Advantage Partner Program is designed to offer our partners exceptional opportunities to grow your business, increase revenue and gain unique solution differentiation.

Find a Partner

For our end-customers, our Tellabs Advantage Partner Program offer best-in-breed services that match specific vertical markets and geographical regions with the end-customers exact needs in mind.

Leadership

Meet the Tellabs leadership team that represents diverse areas of expertise, and who are committed to exceeding the expectations of our employees, partners and customers.

Our Team

The Tellabs’ team is passionate in their pursuit of excellence in the office, their community and the greater industry.

Careers

Visit Tellabs’ online careers pages to see if there is a job opportunity that matches your ambitions. We offer excellent pay, benefits and career advancement possibilities.

Contact

Tellabs offer several easy options for contacting us. You can connect with us today via phone, email, online forms, or through social media channels.